Search Results (1745 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-14763 1 Amazon 1 Aws S3 Encryption Client Java 2026-04-15 5.3 Medium
Missing cryptographic key commitment in the Amazon S3 Encryption Client for Java may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record. To mitigate this issue, upgrade Amazon S3 Encryption Client for Java to version 4.0.0 or later.
CVE-2025-14764 1 Amazon 1 Aws S3 Encryption Client Go 2026-04-15 5.3 Medium
Missing cryptographic key commitment in the Amazon S3 Encryption Client for Go may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record. To mitigate this issue, upgrade Amazon S3 Encryption Client for Go to version 4.0 or later.
CVE-2025-22446 2026-04-15 4.6 Medium
Inadequate encryption strength for some Edge Orchestrator software for Intel(R) Tiber™ Edge Platform may allow an authenticated user to potentially enable escalation of privilege via adjacent access.
CVE-2025-24007 2026-04-15 7.5 High
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). Affected devices only provide weak password obfuscation. An attacker with network access could retrieve and de-obfuscate the safety password used for protection against inadvertent operating errors.
CVE-2025-24525 1 Keysight 1 Ixia Vision 2026-04-15 7.5 High
Keysight Ixia Vision has an issue with hardcoded cryptographic material which may allow an attacker to intercept or decrypt payloads sent to the device via API calls or user authentication if the end user does not replace the TLS certificate that shipped with the device. Remediation is available in Version 6.9.1, released on September 23, 2025.
CVE-2025-2545 1 Best Practical Solutions 1 Request Tracker 2026-04-15 N/A
Vulnerability in Best Practical Solutions, LLC's Request Tracker prior to v5.0.8, where the Triple DES (3DES) cryptographic algorithm is used to protect emails sent with S/MIME encryption. Triple DES is considered obsolete and insecure due to its susceptibility to birthday attacks, which could compromise the confidentiality of encrypted messages.
CVE-2025-26708 2026-04-15 4.2 Medium
There is a configuration defect vulnerability in ZTELink 5.4.9 for iOS. This vulnerability is caused by a flaw in the WiFi parameter configuration of the ZTELink. An attacker can obtain unauthorized access to the WiFi service.
CVE-2025-3838 2026-04-15 N/A
An Improper Authorization vulnerability was identified in the EOL OVA based connect component which is deployed for installation purposes in the customer internal network. Under certain conditions, this could allow a bad actor to gain unauthorized access to the local db containing weakly hashed credentials of the installer. This EOL component was deprecated in September 2023 with end of support extended till January 2024.
CVE-2025-41702 1 Welotec 1 Egos Webgui 2026-04-15 9.8 Critical
The JWT secret key is embedded in the egOS WebGUI backend and is readable to the default user. An unauthenticated remote attacker can generate valid HS256 tokens and bypass authentication/authorization due to the use of hard-coded cryptographic key.
CVE-2025-41223 2026-04-15 4.8 Medium
A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected devices support the TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256 cipher suite, which uses CBC (Cipher Block Chaining) mode that is known to be vulnerable to timing attacks. This could allow an attacker to compromise the integrity and confidentiality of encrypted communications.
CVE-2025-41652 2026-04-15 9.8 Critical
The devices are vulnerable to an authentication bypass due to flaws in the authorization mechanism. An unauthenticated remote attacker could exploit this weakness by performing brute-force attacks to guess valid credentials or by using MD5 collision techniques to forge authentication hashes, potentially compromising the device.
CVE-2024-11022 2026-04-15 5.6 Medium
The authentication process to the web server uses a challenge response procedure which inludes the nonce and additional information. This challenge can be used several times for login and is therefore vulnerable for a replay attack.
CVE-2024-26317 2026-04-15 6.1 Medium
In illumos illumos-gate 2024-02-15, an error occurs in the elliptic curve point addition algorithm that uses mixed Jacobian-affine coordinates, causing the algorithm to yield a result of POINT_AT_INFINITY when it should not. A man-in-the-middle attacker could use this to interfere with a connection, resulting in an attacked party computing an incorrect shared secret.
CVE-2025-7071 2026-04-15 N/A
Padding oracle attack vulnerability in Oberon microsystem AG’s ocrypto library in all versions since 3.1.0 and prior to 3.9.2 allows an attacker to recover plaintexts via timing measurements of AES-CBC PKCS#7 decrypt operations.
CVE-2025-47276 2026-04-15 7.5 High
Actualizer is a single shell script solution to allow developers and embedded engineers to create Debian operating systems (OS). Prior to version 1.2.0, Actualizer uses OpenSSL's "-passwd" function, which uses SHA512 instead of a more suitable password hasher like Yescript/Argon2i. All Actualizer users building a full Debian Operating System are affected. Users should upgrade to version 1.2.0 of Actualizer. Existing OS deployment requires manual password changes against the alpha and root accounts. The change will deploy's Debian's yescript overriding the older SHA512 hash created by OpenSSL. As a workaround, users need to reset both `root` and "Alpha" users' passwords.
CVE-2025-7383 2026-04-15 N/A
Padding oracle attack vulnerability in Oberon microsystem AG’s Oberon PSA Crypto library in all versions since 1.0.0 and prior to 1.5.1 allows an attacker to recover plaintexts via timing measurements of AES-CBC PKCS#7 decrypt operations.
CVE-2025-64304 3 Apple, Fujitv, Google 3 Ios, Fod App, Android 2026-04-15 N/A
"FOD" App uses hard-coded cryptographic keys, which may allow a local unauthenticated attacker to retrieve the cryptographic keys.
CVE-2025-10250 1 Dji 7 Air, Air 2, Mavic 2 and 4 more 2026-04-15 5 Medium
A weakness has been identified in DJI Mavic Spark, Mavic Air and Mavic Mini 01.00.0500. Affected is an unknown function of the component Telemetry Channel. Executing manipulation can lead to use of hard-coded cryptographic key . The attacker needs to be present on the local network. A high complexity level is associated with this attack. The exploitability is told to be difficult. The exploit has been made available to the public and could be exploited. This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2024-38867 2026-04-15 5.9 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS). This could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports.
CVE-2024-23589 2026-04-15 6.8 Medium
Due to outdated Hash algorithm, HCL Glovius Cloud could allow attackers to guess the input data using brute-force or dictionary attacks efficiently using modern hardware such as GPUs or ASICs