Search Results (13857 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-25133 2026-04-15 8.8 High
A flaw was found in the Hive ClusterDeployments resource in OpenShift Dedicated. In certain conditions, this issue may allow a developer account on a Hive-enabled cluster to obtain cluster-admin privileges by executing arbitrary commands on the hive/hive-controllers pod.
CVE-2024-29207 2026-04-15 N/A
An Improper Certificate Validation could allow a malicious actor with access to an adjacent network to take control of the system. Affected Products: UniFi Connect Application (Version 3.7.9 and earlier) UniFi Connect EV Station (Version 1.1.18 and earlier) UniFi Connect EV Station Pro (Version 1.1.18 and earlier) UniFi Connect Display (Version 1.9.324 and earlier) UniFi Connect Display Cast (Version 1.6.225 and earlier) Mitigation: Update UniFi Connect Application to Version 3.10.7 or later. Update UniFi Connect EV Station to Version 1.2.15 or later. Update UniFi Connect EV Station Pro to Version 1.2.15 or later. Update UniFi Connect Display to Version 1.11.348 or later. Update UniFi Connect Display Cast to Version 1.8.255 or later.
CVE-2024-21828 1 Intel 2 Ethernet Adapter Complete Driver Pack, Ethernet Connections Boot Utility Preboot Images And Efi Drivers 2026-04-15 6.7 Medium
Improper access control in some Intel(R) Ethernet Controller Administrative Tools software before version 28.3 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2024-43702 1 Imaginationtech 1 Ddk 2026-04-15 8.1 High
Software installed and run as a non-privileged user may conduct improper GPU system calls to allow unprivileged access to arbitrary physical memory page.
CVE-2024-21767 2026-04-15 9.4 Critical
A remote attacker may be able to bypass access control of Commend WS203VICM by creating a malicious request.
CVE-2024-21741 1 Gigadevice 1 Gd32e103c8t6 2026-04-15 9.8 Critical
GigaDevice GD32E103C8T6 devices have Incorrect Access Control.
CVE-2024-21740 1 Artery 2 At32f415cbt7, At32f421c8t7 2026-04-15 7.4 High
Artery AT32F415CBT7 and AT32F421C8T7 devices have Incorrect Access Control.
CVE-2024-43101 2026-04-15 5.3 Medium
Improper access control for some Intel(R) Data Center GPU Flex Series for Windows driver software before version 31.0.101.4255 may allow an authenticated user to potentially enable denial of service via local access.
CVE-2024-22405 2026-04-15 5.5 Medium
XADMaster is an objective-C library for archive and file unarchiving and extraction. When extracting a specially crafted zip archive XADMaster may not apply quarantine attribute correctly. Such behaviour may circumvent Gatekeeper checks on the system. Only macOS installations are affected. This issue was fixed in XADMaster 1.10.8. It is recommended to upgrade to the latest version. There are no known workarounds for this issue.
CVE-2024-4303 2026-04-15 8.8 High
ArmorX Android APP's multi-factor authentication (MFA) for the login function is not properly implemented. Remote attackers who obtain user credentials can bypass MFA, allowing them to successfully log into the APP.
CVE-2024-42559 1 Hotel Management System Project 1 Hotel Management System 2026-04-15 9.8 Critical
An issue in the login component (process_login.php) of Hotel Management System commit 79d688 allows attackers to authenticate without providing a valid password.
CVE-2024-41934 2026-04-15 5.9 Medium
Improper access control in some Intel(R) GPA software before version 2024.3 may allow an authenticated user to potentially enable denial of service via local access.
CVE-2024-41929 1 Takenaka Engineering 9 Ahd04t-a Firmware, Ahd08t-a Firmware, Ahd16t-a Firmware and 6 more 2026-04-15 8.8 High
Improper authentication vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings.
CVE-2024-23767 1 Hms-networks 1 Anybus X-gateway Ab7832-f 2026-04-15 8.8 High
An issue was discovered on HMS Anybus X-Gateway AB7832-F firmware version 3. The HICP protocol allows unauthenticated changes to a device's network configurations.
CVE-2024-4186 2026-04-15 9.8 Critical
The Edwiser Bridge plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 3.0.5. This is due to the 'eb_user_email_verification_key' default value is empty, and the not empty check is missing in the 'eb_user_email_verify' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the user id. This can only be exploited if the 'Email Verification' setting is enabled.
CVE-2025-32992 2026-04-15 8.5 High
Thermo Fisher Scientific ePort through 3.0.0 has Incorrect Access Control.
CVE-2024-31463 1 Redhat 1 Openshift 2026-04-15 4.7 Medium
Ironic-image is an OpenStack Ironic deployment packaged and configured by Metal3. When the reverse proxy mode is enabled by the `IRONIC_REVERSE_PROXY_SETUP` variable set to `true`, 1) HTTP basic credentials are validated on the HTTPD side in a separate container, not in the Ironic service itself and 2) Ironic listens in host network on a private port 6388 on localhost by default. As a result, when the reverse proxy mode is used, any Pod or local Unix user on the control plane Node can access the Ironic API on the private port without authentication. A similar problem affects Ironic Inspector (`INSPECTOR_REVERSE_PROXY_SETUP` set to `true`), although the attack potential is smaller there. This issue affects operators deploying ironic-image in the reverse proxy mode, which is the recommended mode when TLS is used (also recommended), with the `IRONIC_PRIVATE_PORT` variable unset or set to a numeric value. In this case, an attacker with enough privileges to launch a pod on the control plane with host networking can access Ironic API and use it to modify bare-metal machine, e.g. provision them with a new image or change their BIOS settings. This vulnerability is fixed in 24.1.1.
CVE-2024-31207 1 Vitejs 1 Vite 2026-04-15 5.9 Medium
Vite (French word for "quick", pronounced /vit/, like "veet") is a frontend build tooling to improve the frontend development experience.`server.fs.deny` does not deny requests for patterns with directories. This vulnerability has been patched in version(s) 5.2.6, 5.1.7, 5.0.13, 4.5.3, 3.2.10 and 2.9.18.
CVE-2024-21483 2026-04-15 4.6 Medium
A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 DC (7KM3220-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)). The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the data.
CVE-2025-6531 2026-04-15 4.3 Medium
A vulnerability was found in SIFUSM/MZZYG BD S1 up to 20250611. It has been declared as problematic. This vulnerability affects unknown code of the component RTSP Live Video Stream Endpoint. The manipulation leads to improper access controls. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. This dashcam is distributed by multiple resellers and different names.