Search Results (4607 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-3742 2026-04-15 7.5 High
Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.
CVE-2025-42888 2 Microsoft, Sap 4 Windows, Gui, Gui For Windows and 1 more 2026-04-15 5.5 Medium
SAP GUI for Windows may allow a highly privileged user on the affected client PC to locally access sensitive information stored in process memory during runtime.This vulnerability has a high impact on confidentiality, with no impact on integrity and availability.
CVE-2024-40594 2026-04-15 2.3 Low
The OpenAI ChatGPT app before 2024-07-05 for macOS opts out of the sandbox, and stores conversations in cleartext in a location accessible to other apps.
CVE-2025-40680 2026-04-15 N/A
Lack of sensitive data encryption in CapillaryScope v2.5.0 of Capillary io, which stores both the proxy credentials and the JWT session token in plain text within different registry keys on the Windows operating system. Any authenticated local user with read access to the registry can extract these sensitive values.
CVE-2024-0066 1 Axis 3 Axis Os, Axis Os 2020, Axis Os 2022 2026-04-15 5.3 Medium
Johan Fagerström, member of the AXIS OS Bug Bounty Program, has found that a O3C feature may expose sensitive traffic between the client (Axis device) and (O3C) server. If O3C is not being used this flaw does not apply. Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution.
CVE-2025-0631 2026-04-15 N/A
A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text.
CVE-2024-8689 2026-04-15 N/A
A problem with the ActiveMQ integration for both Cortex XSOAR and Cortex XSIAM can result in the cleartext exposure of the configured ActiveMQ credentials in log bundles.
CVE-2025-40752 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-8863 1 Yugabyte 1 Yugabytedb 2026-04-15 3.7 Low
YugabyteDB diagnostic information was transmitted over HTTP, which could expose sensitive data during transmission
CVE-2025-41718 1 Murrelektronik 4 Firmware Impact67 Pro 54620, Firmware Impact67 Pro 54630, Firmware Impact67 Pro 54631 and 1 more 2026-04-15 7.5 High
A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI.
CVE-2025-36751 1 Growatt 2 Mic3300tl-x, Shinelan-x 2026-04-15 N/A
Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.
CVE-2025-4053 2026-04-15 N/A
The data stored in Be-Tech Mifare Classic card is stored in cleartext. An attacker having access to a Be-Tech hotel guest Mifare Classic card can create a master key card that unlocks all the locks in the building. This issue affects all Be-Tech Mifare Classic card systems. To fix the vulnerability, it is necessary to replace the software, encoder, cards, and PCBs in the locks.
CVE-2025-41647 2026-04-15 5.5 Medium
A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions.
CVE-2024-8070 2026-04-15 8.5 High
CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test credentials in the firmware binary
CVE-2024-9834 1 Baxter 1 Life2000 Ventilator Firmware 2026-04-15 9.3 Critical
Improper data protection on the ventilator's serial interface could allow an attacker to send and receive messages that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.
CVE-2025-40753 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2024-7142 2026-04-15 4.6 Medium
On Arista CloudVision Appliance (CVA) affected releases running on appliances that support hardware disk encryption (DCA-350E-CV only), the disk encryption might not be successfully performed. This results in the disks remaining unsecured and data on them
CVE-2025-10540 1 Imonitor 1 Imonitor Eam 2026-04-15 6.5 Medium
iMonitor EAM 9.6394 transmits communication between the EAM client agent and the EAM server, as well as between the EAM monitor management software and the server, in plaintext without authentication or encryption. An attacker with network access can intercept sensitive information (such as credentials, keylogger data, and personally identifiable information) and tamper with traffic. This allows both unauthorized disclosure and modification of data, including issuing arbitrary commands to client agents.
CVE-2025-1060 2026-04-15 7.5 High
CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure of data when network traffic is being sniffed by an attacker.
CVE-2025-10776 1 Lioncoders 1 Salepro Pos 2026-04-15 3.7 Low
A vulnerability was detected in LionCoders SalePro POS up to 5.5.0. This issue affects some unknown processing of the component Login. Performing manipulation results in cleartext transmission of sensitive information. The attack can be initiated remotely. The attack is considered to have high complexity. The exploitability is assessed as difficult. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.