Search Results (2622 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-1573 2 Iconics, Mitsubishielectric 2 Genesis64, Mc Works64 2026-04-15 5.9 Medium
Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in.
CVE-2025-53118 1 Securden 1 Unified Pam 2026-04-15 9.8 Critical
An authentication bypass vulnerability exists which allows an unauthenticated attacker to control administrator backup functions, leading to compromise of passwords, secrets, and application session tokens stored by the Unified PAM.
CVE-2025-5310 2026-04-15 9.8 Critical
Dover Fueling Solutions ProGauge MagLink LX Consoles expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution.
CVE-2025-5095 1 Burk 1 Arc Solo 2026-04-15 9.8 Critical
Burk Technology ARC Solo's password change mechanism can be utilized without proper authentication procedures, allowing an attacker to take over the device. A password change request can be sent directly to the device's HTTP endpoint without providing valid credentials. The system does not enforce proper authentication or session validation, allowing the password change to proceed without verifying the request's legitimacy.
CVE-2024-2104 1 Jbl 2 Live Pro 2 Tws, Tune Flex 2026-04-15 8.8 High
Due to improper BLE security configurations on the device's GATT server, an adjacent unauthenticated attacker can read and write device control commands through the mobile app service wich could render the device unusable.
CVE-2025-49652 2026-04-15 9.8 Critical
Missing Authentication in the registration feature of Lablup's BackendAI allows arbitrary users to create user accounts that can access private data even when registration is disabled.
CVE-2025-48397 1 Eaton 1 Brightlayer Software Suite 2026-04-15 7.1 High
The privileged user could log in without sufficient credentials after enabling an application protocol. This security issue has been fixed in the latest script patch latest version of of Eaton BLSS (7.3.0.SCP004).
CVE-2025-46275 2026-04-15 9.8 Critical
WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could allow an attacker to create an administrator account without knowing any existing credentials.
CVE-2024-21824 2026-04-15 5.3 Medium
Improper authentication vulnerability in exists in multiple printers and scanners which implement Web Based Management provided by BROTHER INDUSTRIES, LTD. If this vulnerability is exploited, a network-adjacent user who can access the product may impersonate an administrative user. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References].
CVE-2025-43983 1 Kuwfi 1 Cpf908-cp5 2026-04-15 9.1 Critical
KuWFi CPF908-CP5 WEB5.0_LCD_20210125 devices have multiple unauthenticated access control vulnerabilities within goform/goform_set_cmd_process and goform/goform_get_cmd_process. These allow an unauthenticated attacker to retrieve sensitive information (including the device admin username and password), modify critical device settings, and send arbitrary SMS messages.
CVE-2025-42875 1 Sap 2 Netweaver, Sap Netweaver 2026-04-15 6.6 Medium
The SAP Internet Communication Framework does not conduct any authentication checks for features that need user identification allowing an attacker to reuse authorization tokens, violating secure authentication practices causing low impact on Confidentiality, Integrity and Availability of the application.
CVE-2024-22513 2026-04-15 5.5 Medium
djangorestframework-simplejwt version 5.3.1 and before is vulnerable to information disclosure. A user can access web application resources even after their account has been disabled due to missing user validation checks via the for_user method.
CVE-2024-3219 1 Python Software Foundation 1 Cpython 2026-04-15 N/A
The “socket” module provides a pure-Python fallback to the socket.socketpair() function for platforms that don’t support AF_UNIX, such as Windows. This pure-Python implementation uses AF_INET or AF_INET6 to create a local connected pair of sockets. The connection between the two sockets was not verified before passing the two sockets back to the user, which leaves the server socket vulnerable to a connection race from a malicious local peer. Platforms that support AF_UNIX such as Linux and macOS are not affected by this vulnerability. Versions prior to CPython 3.5 are not affected due to the vulnerable API not being included.
CVE-2024-32752 1 Johnsoncontrols 2 Icu, Software House Istar Pro Door Controller 2026-04-15 9.1 Critical
The iSTAR door controllers running firmware prior to version 6.6.B, does not support authenticated communications with ICU, which may allow an attacker to gain unauthorized access
CVE-2024-33616 2026-04-15 5.3 Medium
Admin authentication can be bypassed with some specific invalid credentials, which allows logging in with an administrative privilege. Sharp Corporation states the telnet feature is implemented on older models only, and is planning to provide the firmware update to remove the feature. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References].
CVE-2024-33622 2026-04-15 6.5 Medium
Missing authentication for critical function vulnerability exists in ID Link Manager and FUJITSU Software TIME CREATOR. If this vulnerability is exploited, sensitive information may be obtained and/or the information stored in the database may be altered by a remote authenticated attacker.
CVE-2024-35293 2026-04-15 9.1 Critical
An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.
CVE-2024-35294 2026-04-15 6.5 Medium
An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials.
CVE-2024-35295 2026-04-15 6.1 Medium
A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes.
CVE-2024-35342 2026-04-15 4.6 Medium
Certain Anpviz products allow unauthenticated users to modify or disable camera related settings such as microphone volume, speaker volume, LED lighting, NTP, motion detection, etc. This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera.