Search Results (218 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-25138 2026-04-15 6.5 Medium
In AutomationDirect C-MORE EA9 HMI, credentials used by the platform are stored as plain text on the device.
CVE-2024-28736 1 Debezium Community Project 1 Debezium-ui 2026-04-15 7.1 High
An issue in Debezium Community debezium-ui v.2.5 allows a local attacker to execute arbitrary code via the refresh page function.
CVE-2024-27166 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 7.4 High
Coredump binaries in Toshiba printers have incorrect permissions. A local attacker can steal confidential information. As for the affected products/models/versions, see the reference URL.
CVE-2024-3624 1 Redhat 1 Mirror Registry 2026-04-15 7.3 High
A flaw was found in how Quay's database is stored in plain-text in mirror-registry on the jinja's config.yaml file. This flaw allows a malicious actor with access to this file to gain access to Quay's database.
CVE-2024-3625 1 Redhat 1 Mirror Registry 2026-04-15 7.3 High
A flaw was found in Quay, where Quay's database is stored in plain text in mirror-registry on Jinja's config.yaml file. This issue leaves the possibility of a malicious actor with access to this file to gain access to Quay's Redis instance.
CVE-2025-46809 1 Suse 2 Manager, Manager Server 2026-04-15 5.7 Medium
A Plaintext Storage of a Password vulnerability in SUSE exposes the credentials for the HTTP proxy in the log files. This issue affects Container suse/manager/4.3/proxy-httpd:4.3.16.9.67.1: from ? before 4.3.33-150400.3.55.2; Container suse/manager/5.0/x86_64/proxy-httpd:5.0.5.7.23.1: from ? before 5.0.14-150600.4.17.1; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Image SLES15-SP4-Manager-Proxy-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; SUSE Manager Proxy Module 4.3: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2.
CVE-2025-43005 2026-04-15 4.3 Medium
SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data.
CVE-2025-65009 2026-04-15 N/A
In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) admin password is stored in configuration file as plaintext and can be obtained by unauthorized user by direct references to the resource in question. The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable.
CVE-2025-61680 2 Jaketcooper, Minecraft 2 Minecraft-rcon, Minecraft 2026-04-15 N/A
Minecraft RCON Terminal is a VS Code extension that streamlines Minecraft server management. Versions 0.1.0 through 2.0.6 stores passwords using VS Code's configuration API which writes to settings.json in plaintext. This issue is fixed in version 2.1.0.
CVE-2025-2500 2026-04-15 7.4 High
A vulnerability exists in the SOAP Web services of the Asset Suite versions listed below. If successfully exploited, an attacker could gain unauthorized access to the product and the time window of a possible password attack could be expanded.
CVE-2025-25051 1 Automationdirect 1 Click Plc 2026-04-15 6.1 Medium
An attacker could decrypt sensitive data, impersonate legitimate users or devices, and potentially gain access to network resources for lateral attacks.
CVE-2025-25727 2026-04-15 6.2 Medium
Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to store passwords in cleartext.
CVE-2024-39922 2026-04-15 4.6 Medium
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs.
CVE-2024-42197 1 Hcltech 1 Workload Scheduler 2026-04-15 5.5 Medium
HCL Workload Scheduler stores user credentials in plain text which can be read by a local user.
CVE-2024-43378 1 Nixos 1 Calamares-nixos-extensions 2026-04-15 7.8 High
calamares-nixos-extensions provides Calamares branding and modules for NixOS, a distribution of GNU/Linux. Users who installed NixOS through the graphical installer who used manual disk partitioning to create a setup where the system was booted via legacy BIOS rather than UEFI; some disk partitions are encrypted; but the partitions containing either `/` or `/boot` are unencrypted; have their LUKS disk encryption key file in plain text either in `/crypto_keyfile.bin`, or in a CPIO archive attached to their NixOS initrd. `nixos-install` is not affected, nor are UEFI installations, nor was the default automatic partitioning configuration on legacy BIOS systems. The problem has been fixed in calamares-nixos-extensions 0.3.17, which was included in NixOS. The current installer images for the NixOS 24.05 and unstable (24.11) channels are unaffected. The fix reached 24.05 at 2024-08-13 20:06:59 UTC, and unstable at 2024-08-15 09:00:20 UTC. Installer images downloaded before those times may be vulnerable. The best solution for affected users is probably to back up their data and do a complete reinstallation. However, the mitigation procedure in GHSA-3rvf-24q2-24ww should work solely for the case where `/` is encrypted but `/boot` is not. If `/` is unencrypted, then the `/crypto_keyfile.bin` file will need to be deleted in addition to the remediation steps in the previous advisory. This issue is a partial regression of CVE-2023-36476 / GHSA-3rvf-24q2-24ww, which was more severe as it applied to the default configuration on BIOS systems.
CVE-2024-43659 2026-04-15 7.2 High
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-6561 2026-04-15 9.8 Critical
Certain hybrid DVR models ((HBF-09KD and HBF-16NK)) from Hunt Electronic have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.
CVE-2024-45283 2026-04-15 6 Medium
SAP NetWeaver AS for Java allows an authorized attacker to obtain sensitive information. The attacker could obtain the username and password when creating an RFC destination. After successful exploitation, an attacker can read the sensitive information but cannot modify or delete the data.
CVE-2025-7357 2026-04-15 N/A
LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs.
CVE-2025-6560 2026-04-15 9.8 Critical
Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.  The affected models are out of support; replacing the device is recommended.