| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Incorrect Permission Assignment for Critical Resource in Owl opds 2.2.0.4 allows File Manipulation via a crafted network request. |
| Incorrect Permission Assignment for Critical Resource in Owl opds 2.2.0.4 allows File Manipulation via a crafted network request. |
| Barracuda RMM versions prior to 2025.2.2 contain a privilege escalation vulnerability that allows local attackers to gain SYSTEM-level privileges by exploiting overly permissive filesystem ACLs on the C:\Windows\Automation directory. Attackers can modify existing automation content or place attacker-controlled files in this directory, which are then executed under the NT AUTHORITY\SYSTEM account during routine automation cycles, typically succeeding within the next execution cycle. |
| HP System Event Utility might allow denial of service with elevated arbitrary file writes. This potential vulnerability was
remediated with HP System Event Utility version 3.2.16. |
| File Browser provides a file managing interface within a specified directory and it can be used to upload, delete, preview, rename and edit files. Prior to version 2.61.1, a broken access control vulnerability in the TUS protocol DELETE endpoint allows authenticated users with only Create permission to delete arbitrary files and directories within their scope, bypassing the intended Delete permission restriction. Any multi-user deployment where administrators explicitly restrict file deletion for certain users is affected. This issue has been patched in version 2.61.1. |
| Sensitive information disclosure due to improper configuration of a headless browser. The following products are affected: Acronis Cyber Protect 17 (Linux, Windows) before build 41186. |
| An Incorrect Permission Assignment for Critical Resource vulnerability in the On-Box Anomaly detection framework of Juniper Networks Junos OS Evolved on PTX Series allows an unauthenticated, network-based attacker to execute code as root.
The On-Box Anomaly detection framework should only be reachable by other internal processes over the internal routing instance, but not over an externally exposed port. With the ability to access and manipulate the service to execute code as root a remote attacker can take complete control of the device.
Please note that this service is enabled by default as no specific configuration is required.
This issue affects Junos OS Evolved on PTX Series:
* 25.4 versions before 25.4R1-S1-EVO, 25.4R2-EVO.
This issue does not affect Junos OS Evolved versions before 25.4R1-EVO.
This issue does not affect Junos OS. |
| HCL BigFix Platform is affected by insecure permissions on private cryptographic keys. The private cryptographic keys located on a Windows host machine might be subject to overly permissive file system permissions. |
| Files or Directories Accessible to External Parties, Incorrect Permission Assignment for Critical Resource vulnerability in Hallo Welt! GmbH BlueSpice (Extension:NSFileRepo modules) allows Accessing Functionality Not Properly Constrained by ACLs, Bypassing Electronic Locks and Access Controls.This issue affects BlueSpice: from 5.1 through 5.1.3, from 5.2 through 5.2.0.
HINT: Versions provided apply to BlueSpice MediaWiki releases. For Extension:NSFileRepo the affected versions are 3.0 < 3.0.5 |
| IDC SFX2100 Satalite Recievers set the `/etc/resolv.conf` file to be world-writable by any local user, allowing DNS resolver tampering that can redirect network communications, facilitate man-in-the-middle attacks, and cause denial of service. |
| Incorrect permission assignment (world-writable file) in /etc/udhcpc/default.script in International Data Casting (IDC) SFX2100 Satellite Receiver allows a local unprivileged attacker to potentially execute arbitrary commands with root privileges (local privilege escalation and persistence) via modification of a root-owned, world-writable BusyBox udhcpc DHCP event script, which is executed when a DHCP lease is obtained, renewed, or lost. |
| The Winsock2ProtocolCatalogMutex mutex in Windows NT 4.0 has inappropriate Everyone/Full Control permissions, which allows local users to modify the permissions to "No Access" and disable Winsock network connectivity to cause a denial of service, aka the "Winsock Mutex" vulnerability. |
| Shared memory sections and events in IBM DB2 8.1 have default permissions of read and write for the Everyone group, which allows local users to gain unauthorized access, gain sensitive information, such as cleartext passwords, and cause a denial of service. |
| BlackICE PC Protection and Server Protection installs (1) firewall.ini, (2) blackice.ini, (3) sigs.ini and (4) protect.ini with Everyone Full Control permissions, which allows local users to cause a denial of service (crash) or modify configuration, as demonstrated by modifying firewall.ini to contain a large firewall rule. |
| Incorrect privilege assignment in Bluetooth in Maintenance mode prior to SMR Apr-2026 Release 1 allows physical attackers to bypass Extend Unlock. |
| The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise. |
| An Incorrect Permission Assignment for Critical Resource vulnerability in the file system used in B&R APROL <4.4-01 may allow an authenticated local attacker to read and alter the configuration of another engineering or runtime user. |
| Improper permission control in the mobile application (com.transsion.aivoiceassistant) can lead to the launch of any unexported component. |
| For a short time they PTY is set to mode 666, allowing any user on the system to connect to the screen session. |
| A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not require authentication to access critical resources. An attacker with network access could retrieve sensitive information from certain data records, including obfuscated safety passwords. |