Export limit exceeded: 21403 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (21403 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-4466 1 Ipcop 1 Ipcop 2026-04-15 N/A
IPCop versions up to and including 2.1.9 contain an authenticated remote code execution vulnerability within the web-based administration interface. The email configuration component inserts user-controlled values, including the EMAIL_PW parameter, directly into system-level operations without proper input sanitation. By modifying the email password field to include shell metacharacters and issuing a save-and-test-mail action, an authenticated attacker can execute arbitrary operating system commands with the privileges of the web interface, resulting in full system compromise.
CVE-2023-34873 2026-04-15 N/A
On MOBOTIX P3 cameras before MX-V4.7.2.18 and Mx6 cameras before MX-V5.2.0.61, the tcpdump feature does not properly validate input, which allows authenticated users to execute code.
CVE-2025-34103 1 Barco 1 Wepresent Wipg-1000p Firmware 2026-04-15 N/A
An unauthenticated command injection vulnerability exists in WePresent WiPG-1000 firmware versions prior to 2.2.3.0, due to improper input handling in the undocumented /cgi-bin/rdfs.cgi endpoint. The Client parameter is not sanitized before being passed to a system call, allowing an unauthenticated remote attacker to execute arbitrary commands as the web server user.
CVE-2024-51228 1 Totolink 4 A3002ru Firmware, N150rt Firmware, N300rt Firmware and 1 more 2026-04-15 6.8 Medium
An issue in TOTOLINK-CX-A3002RU V1.0.4-B20171106.1512 and TOTOLINK-CX-N150RT V2.1.6-B20171121.1002 and TOTOLINK-CX-N300RT V2.1.6-B20170724.1420 and TOTOLINK-CX-N300RT V2.1.8-B20171113.1408 and TOTOLINK-CX-N300RT V2.1.8-B20191010.1107 and TOTOLINK-CX-N302RE V2.0.2-B20170511.1523 allows a remote attacker to execute arbitrary code via the /boafrm/formSysCmd component.
CVE-2024-5241 2026-04-15 4.7 Medium
A vulnerability was found in Huashi Private Cloud CDN Live Streaming Acceleration Server up to 20240520. It has been classified as critical. Affected is an unknown function of the file /manager/ipconfig_new.php. The manipulation of the argument dev leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-265992.
CVE-2024-44072 1 Buffalo Inc 18 Wex 1166dhp, Wex 1166dhp2, Wex 1166dhps and 15 more 2026-04-15 5.7 Medium
OS command injection vulnerability exists in BUFFALO wireless LAN routers and wireless LAN repeaters. If a user logs in to the management page and sends a specially crafted request to the affected product from the product's specific management page, an arbitrary OS command may be executed.
CVE-2024-43778 1 Takenaka Engineering 9 Ahd04t-a Firmware, Ahd08t-a Firmware, Ahd16t-a Firmware and 6 more 2026-04-15 8.8 High
OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings.
CVE-2024-53375 1 Tp-link 1 Archer Axe75 Firmware 2026-04-15 8 High
An Authenticated Remote Code Execution (RCE) vulnerability affects the TP-Link Archer router series. A vulnerability exists in the "tmp_get_sites" function of the HomeShield functionality provided by TP-Link. This vulnerability is still exploitable without the activation of the HomeShield functionality.
CVE-2024-53688 2026-04-15 7.2 High
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in AE1021 firmware versions 2.0.10 and earlier and AE1021PE firmware versions 2.0.10 and earlier, which may allow a logged-in user to execute an arbitrary OS command using a crafted HTTP request.
CVE-2024-53992 1 Emd115 1 Unzip Bot 2026-04-15 N/A
unzip-bot is a Telegram bot to extract various types of archives. Users could exploit unsanitized inputs to inject malicious commands that are executed through subprocess.Popen with shell=True. Attackers can exploit this vulnerability using a crafted archive name, password, or video name. This vulnerability is fixed in 7.0.3a.
CVE-2024-54008 2026-04-15 7.2 High
An authenticated Remote Code Execution (RCE) vulnerability exists in the AirWave CLI. Successful exploitation of this vulnerability could allow a remote authenticated threat actor to run arbitrary commands as a privileged user on the underlying host.
CVE-2024-43688 2 Openbsd, Vixie 2 Openbsd, Cron 2026-04-15 7.3 High
cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring.
CVE-2024-5403 2026-04-15 7.2 High
ASKEY 5G NR Small Cell fails to properly filter user input for certain functionality, allowing remote attackers with administrator privilege to execute arbitrary system commands on the remote server.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).